Hrilhfiahna
Uninterrupted protection atana thil pawimawh tak chu he dry box desiccator tan hian a power-failure resilience hi a ni. System ah hian memory function a awm a, chu chuan outage hnuah settings a vawng reng thin. Chu aia pawimawh zawk chu, a sealing sang zawk leh residual desiccant capacity hian power hloh atanga darkar 24 chhungin internal humidity rise chu 10% hnuai lamah a awm reng a, short-term outages-ah contents a humhim a ni.
1.Technical Parameter hman dan tur: 1.1.
|
Product Hming |
Coin Cell dahna tur Electronic Dry Cabinet a ni |
|
Pawn lam Dimension a ni |
w1200*D710*h1940MM a ni |
|
Chhung lam Dimension |
w1198*d680*h1840mm a ni |
|
Volume dik tak a ni |
1428L |
|
Humidity Range a ni |
20-60%/10-20% |
|
Bungrua |
1.2mm a vawt-rolled steel sheet a ni |
|
Windows ah chuan |
4MM anti-riot tempered glass, kawngkhar frame pahnih siam a ni |
|
Hnathawh Voltage a ni |
220V |
|
Hnathawh theihna |
26W |
2.Control Technology: Microcomputer hmanga fuzzy humidity inertial system control technology hmanga siam a ni. Sensor hi United States atanga lakluh a ni a, Honeywell brand a ni a, digital frequency output port a nei a, versatility sang tak, thlak awlsam, accuracy sang, kum tin drift tlem ber, leh anti-interference theihna chak tak a pe a ni.
3.Humidity Control Module: He in hi South Korean engineering plastic hmanga siam a ni a, heat-degree 300 aia sang a tuar thei a, kum 30 chuang service life atan design a ni. Molecular sieve hi Germany atanga lakluh a ni a, double-memory alloy spring hi Sweden atanga lakluh a ni a, hei hian a chhe thei lo a, a chau thei lo bawk. He moisture-proof cabinet hi motor-free a ni a, thermal insulation, magnetic isolation, anti-static, dust-proof, anti-theft, power consumption tlem, leh consumables nei lo a ni. Hei hian boruak tichhe lo, energy-saving, silent, pollution-free, leh drip{15}}proof a siam a ni.
4.Display: 3-window digital display (LED digital tube: temperature atan 1, humidity atan 1, leh dynamic humidity display atan 1), chamber chhunga humidity inthlak danglamna chu awlsam taka hmuh theih a ni.
5.Power-off venhimna leh memory function: Power a tlakchhiat hnuah system hian chamber chhunga humidity sang chu 10% aia tlem (darkar 24 chhungin) a enfiah thin. Memory function hian power outage hnua reset a ngai tawh lo.
6.Operating Principle: Humidity sensor (humidity leh temperature signal) → microcomputer (CPU central processing unit) → heater (polymer PTC constant temperature heating module) → intelligent shape memory alloy (temperature a zirin alloy pianzia a inthlak thin) → balance spring (standard balance spring nen alloy inang).








